Subject: Re: c-4 AC Bolower ? / Please Help
From: "George Csahanin" <georgec(at)lintv.com>
Subject: Re: c-4 AC Bolower ? / Please Help
Lines: 67
NNTP-Posting-Host: 65.68.232.25
Date: Sat, 18 Jun 2005 04:43:45 GMT
________________________________________________
Check your vaccuum lines to the a/c system, and the check valve in the
vaccuum line just front of teh firewall. You either have a vaccuum leak or
blockage, or a air door damper control motor (run by vaccuum) failure...
I had something similar in my 84, but that was 10 years ago, and it is a azy
memory. Was a clogged vaccuum check valve.
-GC
"`Key" <Key(at)Ya.Net> wrote in message
news:oyYpe.31384$PR6.23701(at)tornado.texas.rr.com...
> "Greg" <not(at)home.now> wrote in message
> news:6mhga1p65io4kbpl6k5h11ti2njbqom8jo(at)4ax.com...
> > what year model c4 does it have manual or automatic A/C
> > control?
>
> 1984 / manual A/C control
>
> > sounds like you have a air door problem, get me some info
> > and i will
> > try to help you with it.
>
> air door problem?
> Sorry, I don`t understand what that is.
>
> > not trying to be a smart ass but you might
> > want to get another mechanic, this is not a very complex
> > system.
>
> Understand and agree
> but my mechanic is a GM mr. goodwrench (worked at the Cad
> store for many years)
> and seems to be pretty knowledgable, considering the other
> work he has done for me in the past.
> He admits that he has not worked on Vetts that much.
> Its really hard to find a local that even wants to work on
> this 84 vette.
>
> Thank You for any help you can provide Greg
>
> g`day
> ---
> "Key"
>
>
> > On Sat, 04 Jun 2005 12:36:00 GMT, "`Key" <Key(at)Ya.Net>
> > wrote:
> >
> >>thanks in advance for any help. my mechanic seems to be
> >>stumped.
> >>have an 84 vette with ac blowing problems.
> >>the ac is blowing cold but the air only comes out the
> >>middle
> >>vents.
> >>It does not blow out the vents on the ends.
> >>any advice ?
> >>
> >>thanks
> >
>
>
>
From: "`Key" <Key(at)Ya.Net>
Subject: Re: c-4 AC Bolower ? / Please Help
Lines: 26
Date: Sat, 18 Jun 2005 21:04:59 GMT
NNTP-Posting-Host: 24.242.99.172
________________________________________________
"George Csahanin" <georgec(at)lintv.com> wrote in message
news:5ENse.2191$kX4.1657(at)newssvr30.news.prodigy.com...
> Check your vaccuum lines to the a/c system, and the check
> valve in the
> vaccuum line just front of teh firewall. You either have a
> vaccuum leak or
> blockage, or a air door damper control motor (run by
> vaccuum) failure...
>
>
> I had something similar in my 84, but that was 10 years
> ago, and it is a azy
> memory. Was a clogged vaccuum check valve.
>
> -GC
Thanks for the reply G.C.
Will pass the info on to my mechanic.
g`day
--
"Key"
---snip---
From: "Marty" <pyromarty(at)starband.net>
Subject: C-4 Cluster bulbs
Lines: 14
Date: Sun, 10 Oct 2004 12:20:50 -0500
________________________________________________
With a quick google search I came up with #891 halogen bulbs. Haynes doesn`t
say anything about the cluster bulbs, just says non serviceable.
The previous owner or a so-called mechanic stuck 194 bulbs in the thing and
duct taped the caps on.
Is this the right bulb? All searches refer to this bulb as an exterior bulb,
namely the 3rd stop lamp. Price is generally $7.
Can`t imagine what the dealer will charge if I have to get them from him
tomorrow.
Thanks for any help,
Marty
NEXT POSTS: br> br> br>
| | |